Emergency fire pump.
Pacer 200 gpm 2 emergency fire fighting water pump kit.
Cargo ships 6000 grt above 2 8 bar 1000 6000 grt 2 6 bar passenger ships.
When all the fire pumps are out of action either by disabling the pumps or their source of power emergency fire pump can still be used.
On ships every machinery is provided with a backup system i e.
A fire pump is a part of a fire sprinkler system s water supply and powered by electric diesel or steam.
The pump s capacity required in the fss code chapter 12 paragraph 2 2 1 1 shall be carried out and if the emergency fire pump is the main supply of water for any fixed fire extinguishing system provided to protect the spaces where the main fire pumps are located the pump shall have the capacity for this system.
44 0 1953 454540 sales.
Emergency fire pumps in the event of fire it is crucial that sufficient water is available at sufficient pressure in order to be able to extinguish the fire.
It is a fixed emergency fire pump independently driven by self cooled compression ignition engine or an electric motor which power is supply from emergency generator.
One duplex or spare system or an emergency backup system.
The pump provides water flow at a higher pressure to the sprinkler system risers and hose standpipes.
Requirement for emergency fire pump on board as per solas.
Pump hire in stock immediately for emergency uand maintenance or for on going fire protection.
Diesel power source of pump started in cold condition of 0 c by hand or by power at.
Capable of delivering 2 jets of water with minimum pressure at a 3 rd hydrant not a solas requirement not less than 2 1 bar.
For this purpose several fire pumps are required.
For firefighting system the fire pump is an important machinery and if it fails the complete fire line will become inactive.
44 0 1953 456968 email protected.
M hr in any case pressure.
What is emergency fire pump.
The pump intake is either connected to the public underground water supply piping or a static water source e g tank reservoir lake.
Solas requirement of emergency fire pump not less than 40 of the total capacity of main fire pump not less than 25 cu.
Capacity not less than 40 of total required capacity of the fire pumps but in any case not less than 25 m 3 hr.
A seawater pump which supply the ship fire main when the machinery space pump is not available.